Proxy recorder security, privacy, and limits
Authorised use
Section titled “Authorised use”What is captured
Section titled “What is captured”The Capture setting limits what the recorder keeps. It is enforced inside the recorder itself; anything not in the chosen mode is never uploaded.
| Mode (console label) | Captured |
|---|---|
| full (Everything) | Method, URL, status, timings, headers, and bodies up to the body limit, plus WebSocket frames |
| headers (Headers only) | Method, URL, status, timings, and headers. Bodies are never stored. |
| metadata (Just the requests) | Method, URL, status, and timings only |
Bodies larger than the body limit are not captured at all. There is no truncated prefix. The flow is still listed, with the note Body larger than <limit> was not captured and, when known, its size. Bodies up to the limit are stored in full.
Sensitive values are hidden by default
Section titled “Sensitive values are hidden by default”Recordings are stored in full but shown redacted, in the console, the API, MCP, HAR exports, and conversion.
- Headers:
authorization,proxy-authorization,cookie,set-cookie,x-api-key,x-auth-token. - Keys
password,token,access_token,refresh_token,client_secret,secret,api_keyin JSON bodies, form-encoded (application/x-www-form-urlencoded) bodies, and URL query strings. - WebSocket frame payloads get the same treatment (JSON and form keys). Binary frames, and frames over 256 KiB, are masked entirely unless a workspace admin reveals them. A frame payload larger than 256 KiB is truncated at capture and flagged
truncated. - Custom rules under Hide when viewing add your own header names, JSON keys, or regular expressions.
Reveal is for workspace admins only and is audited. Viewing the proxy password, rotating it, and exporting a HAR with sensitive values are also workspace-admin actions.
Access control
Section titled “Access control”- Gateway mode: a device must present the proxy credentials or be paired. Anything else gets a 407 response. Pairing allow-lists the device’s public IP address for a limited time; other devices behind the same public address are allowed too while it is active, and pairings can be revoked. If the phone reaches the pairing page over IPv6 while the proxy is IPv4, pairing may not apply; use the credentials.
- Direct mode: credentials, or an allow-list of source addresses (Allowed devices). The allow-list only works because the recorder’s Service keeps the real client address; see the direct-mode requirement in the overview.
- The proxy password is sent as HTTP Basic over a plain HTTP proxy. Phone proxy settings cannot use HTTPS proxies, so it is not encrypted on the way to the recorder. Treat it as a short-lived credential: rotate it after a session, never reuse a real account password, and prefer pairing or direct mode on networks you do not trust.
- Recorder egress: loopback, link-local, and cloud metadata addresses are always blocked. On shared datacenters, private address ranges are blocked too.
The recorder certificate
Section titled “The recorder certificate”Each recorder has its own certificate authority (CA). Its private key stays in encrypted storage and in the recorder’s memory; it never leaves them. Rotate certificate in Settings replaces it (install the new one on your devices). Deleting a recorder deletes its CA.
Retention
Section titled “Retention”Recordings are kept until you delete them. Deleting a recorder keeps its recordings. Deleting a recording removes its requests and stored bodies. Your plan sets how many recorders can run at once and the recording storage cap; the New proxy recorder dialog and your plan page show your values.
A recorder stops on its own for one of these reasons, shown in the console:
| Reason | Console wording |
|---|---|
| manual | Stopped manually |
| idle | Stopped: idle timeout |
| session time limit | Stopped: session time limit |
| plan limit | Stopped: plan limit |
| storage or flow-count limit | Stopped: storage or flow-count limit reached (also applies when a recording reaches the flow-count limit) |
| error | Stopped: error |
Defaults and limits
Section titled “Defaults and limits”These are defaults and ranges; per-plan caps are shown in the console.
| Setting | Default | Range / limit |
|---|---|---|
| Body size limit (Bodies up to) | 1 MiB | 1 KiB to 10 MiB |
| Idle timeout (Stop after idle) | 30 minutes | 1 to 240 minutes |
| Session time limit (Maximum minutes in total) | 240 minutes | 1 to 240 minutes, on every plan |
| Flows per recording (flow-count limit) | 50,000 | fixed |
| Pairing code lifetime | 10 minutes | fixed |
| Pairing lifetime | 60 minutes | fixed |
| WebSocket frame payload | 256 KiB | larger payloads are truncated |
| Host include / exclude patterns, redaction rules, allowed source addresses | up to 50 each | fixed |
| HTTP test conversion | 50 requests | fixed |
| Virtual service mock conversion | 200 transactions | fixed |
| HAR export | 5,000 requests | 64 MiB of bodies |
What cannot be intercepted
Section titled “What cannot be intercepted”- Apps that pin certificates. They refuse the recorder CA by design.
- Android 7 and later apps that do not trust user-installed certificates. Chrome works; many apps do not.
- Non-HTTP traffic. Raw TCP and other protocols are not captured.
- iOS configuration profiles (
.mobileconfig) are not supported; install the certificate manually as described in Record from iOS.
You can recognise a rejected certificate: the host appears under Needs attention with the note “App rejected the recorder CA”. It is also visible on the live view as a flow with a TLS error.